Reference data from EU CLP Annex VI and published regulations — verify against your supplier's SDS before use.

Build a label

Response · precautionary statement

P375 — Fight fire remotely due to the risk of explosion.

Response statements describe what to do once exposure, a spill or a fire has happened. No substance with a harmonised EU classification carries this code.

EU CLP: currentUS OSHA HazCom: currentUS HazCom 2012: currentUN GHS: current

01 · Wording

What P375 says

Official

Fight fire remotely due to the risk of explosion.

Category

Response · GHS revision 9

Does your label need P375? That depends on the hazard classes of your product, on whether it goes to the public or to professionals, and on what else is already on the label — Annex IV column 5 lets one statement remove another. Work it out from a classification →

02 · Languages

P375 in the 24 official EU languages

A label put on the market in an EU country must carry the wording of that country's own language version of CLP — not a translation of the English one. These 24 lines are quoted from the consolidated regulation, Annex IV, and are the text to print.

LanguageOfficial wording of P375
BG български Bulgarian Гасете пожара от разстояние поради опасност от експлозия.
ES español Spanish Luchar contra el incendio a distancia, dado el riesgo de explosión.
CS čeština Czech Kvůli nebezpečí výbuchu haste z dostatečné vzdálenosti.
DA dansk Danish Bekæmp branden på afstand på grund af eksplosionsfare.
DE Deutsch German Wegen Explosionsgefahr Brand aus der Entfernung bekämpfen.
ET eesti Estonian Plahvatusohu tõttu teha kustutustöid eemalt.
EL ελληνικά Greek Προσπαθήστε να σβήσετε την πυρκαγιά από απόσταση, επειδή υπάρχει κίνδυνος έκρηξης.
EN English English Fight fire remotely due to the risk of explosion.
FR français French Combattre l’incendie à distance à cause du risque d’explosion.
GA Gaeilge Irish Téigh i gcianghleic leis an dóiteán mar gheall ar an mbaol pléasctha.
HR hrvatski Croatian Gasiti s veće udaljenosti zbog opasnosti od eksplozije.
IT italiano Italian Rischio di esplosione. Utilizzare i mezzi estinguenti a grande distanza.
LV latviešu Latvian Dzēst ugunsgrēku no attāluma eksplozijas riska dēļ.
LT lietuvių Lithuanian Gaisrą gesinti iš toli dėl sprogimo pavojaus.
HU magyar Hungarian A tűz oltását robbanásveszély miatt távolból kell végezni.
MT Malti Maltese Itfi n-nar mill-bogħod minħabba r-riskju ta' splużjoni.
NL Nederlands Dutch Op afstand blussen omwille van ontploffingsgevaar.
PL polski Polish Z powodu ryzyka wybuchu gasić pożar z odległości.
PT português Portuguese Combater o incêndio à distância, devido ao risco de explosão.
RO română Romanian Stingeți incendiul de la distanță din cauza pericolului de explozie.
SK slovenčina Slovak Z dôvodu nebezpečenstva výbuchu požiar haste z diaľky.
SL slovenščina Slovenian Gasiti z večje razdalje zaradi nevarnosti eksplozije.
FI suomi Finnish Sammuta palo etäältä räjähdysvaaran takia.
SV svenska Swedish Bekämpa branden på avstånd på grund av explosionsrisken.

Source: CELEX:02008R1272-20260501, Annex IV. © European Union, https://eur-lex.europa.eu — only the electronic Official Journal of the European Union is authentic. Irish is one of the 24 official languages and its H and P texts are printed inside the multilingual Annex tables, but no consolidated CLP has ever been published in Irish — which is why an Irish-primary label cannot be built here.

Where P375 is current

GHS is a United Nations model text, revised every two years, and each jurisdiction adopts a revision on its own timetable. A code can be legally current in one system and deleted in another — that is normal, not an error.

JurisdictionBasisStatus of P375
EU CLP Regulation (EC) 1272/2008 CLP Annex IV, Part 2 (consolidated) Current
US OSHA HazCom 29 CFR 1910.1200 Appendix C UN GHS Rev.7 (final rule of 20 May 2024) Current
US HazCom 2012 legacy · GHS Rev.3 UN GHS Rev.3, Annex 3 Current
UN GHS Rev.11 (2025) UN GHS Rev.11, Annex 3 Current

Currently in force under: EU CLP, US OSHA HazCom, US HazCom 2012, UN GHS. Sources: EU CLP · US OSHA HazCom · US HazCom 2012 · UN GHS

04 · On a label

P375 usually appears combined

CLP Annex IV defines combined statements as single label elements. P375 is a component of 3 of them — this is how you will actually see it printed.

CodeCombined statement
P370+P380+P375 In case of fire: evacuate area. Fight fire remotely due to the risk of explosion. CLP verbatim: In case of fire: Evacuate area. Fight fire remotely due to the risk of explosion.
P371+P380+P375 In case of major fire and large quantities: evacuate area. Fight fire remotely due to the risk of explosion. CLP verbatim: In case of major fire and large quantities: Evacuate area. Fight fire remotely due to the risk of explosion.
P370+P380+P375+P378 In case of fire: evacuate area. Fight fire remotely due to the risk of explosion. Use the specified media to extinguish. CLP verbatim: In case of fire: Evacuate area. Fight fire remotely due to the risk of explosion. [Use … to extinguish].

Substances carrying P375

No substance with a harmonised classification in CLP Annex VI carries this code. That does not mean it is unused — suppliers apply it to their own mixtures.

All precautionary statements

The full list of P-codes with the jurisdiction switch lives on the precautionary statements hub. For the hazard side, see hazard statements (H-codes).

Wording quoted from the regulation named above. Substance counts come from harmonised classifications in CLP Annex VI — the statements on a real product also depend on the supplier's own classification. Always check the supplier safety data sheet.

Get the free GHS / CLP / OSHA deadline calendar

Verified 2026–2029 compliance dates in one PDF — plus alerts when the rules change.